z/OS MVS System Messages, Vol 8 (IEF-IGD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


IGD025I

z/OS MVS System Messages, Vol 8 (IEF-IGD)
SA38-0675-02

IGD025I
SMS START FAILED UNEXPECTED ERROR ININITIALIZATION PROCESSING

Explanation

During SMS initialization processing, an error occurred, and the storage management subsystem was unable to successfully start or restart. Possible errors are an abnormal end, or a failure in the address space start facility. If one of these two errors is the cause of the SMS start failure, IGD025I will be preceded by IGD300I or IGD021I. Other possible errors are that the reserve pc linkage index failed, the create pc entry table failed, the connect pc entry table failed, or there is a control block length error. If a control block length error occurs, IGD025I will be followed by IGD306I, containing the return and reason codes.

System action

The system does not start or restart the storage management subsystem. Jobs that refer to SMS managed data sets will not start or end. Also, data sets cannot be created; and storage management subsystem data sets cannot be unallocated.

Operator response

Issue the SET SMS command to start the storage management subsystem. If that fails, then tell the system programmer about this situation.

Programmer response

If message IGD300I or IGD021I preceded IGD025I, follow the programmer response provided for that message.

Source

DFSMSdfp

Routing code

2,10

Descriptor code

4

Go to the previous page Go to the next page