IGD086I z/OS MVS System Messages, Vol 8 (IEF-IGD) SA38-0675-02 |
|
IGD086I DATA SET SEPARATION PROFILE dsn {COULD
NOT BE ACCESSED. SMS RETURN CODE rc func REASON
CODE rsn. | CONTAINED A SYNTAX ERROR ON LINE line POSITION pos.} ExplanationThis message is generated at the time a new SMS source control data set (SCDS) has been activated or an active control data set (ACDS) has been switched. The control data set specified a data set separation profile that could not be accessed or that failed syntax checking. In the message text:
System actionProcessing continues without data set separation support. Operator responseContact the system programmer. System programmer responseResolve the access error and reactivate the configuration. For profile access failures, make sure that the data set is cataloged and that the SCDS base configuration contains the correct profile data set name. A profile that reports a syntax error or an access error with SMS as the function detecting the error indicates that the profile has been modified without validation. Run SCDS validation and reactivate the configuration. If the error persists after successful validation, contact the IBM® Support Center and report the error. SourceStorage Management Subsystem (DFSMS) ModuleIGDOPST2 |