Coupling facility request response time (service time)

z/OS MVS Setting Up a Sysplex
SA23-1399-00

Service time is accumulated from the time MVS™ issues a CF command to the CF until the return from the command is recognized by MVS. It includes the time spent on the CF links, the processing within the CF and time for MVS to recognize that the command has completed. Service time in microseconds is recorded for each structure used by each system.

Given the model numbers in the header of each column, Table 1 shows the best service times you could possibly expect given the model numbers in the header of each column, a sender of that model, across the fastest link technology available on that model to a CF of the same technology. The lower number in each range applies to requests with little or no data to transfer (such as lock requests). The higher number to the requests with larger amounts of data (such as DB2® cache updates).

Table 1. Service times
  2064-114 to 1xx 2084 3xx to 3xx z9® EC/BC z10 EC/BC z114 / z196
SYNC 25 - 50 10 - 25 7 - 20    
ASYNC 150 - 450 100 - 300 80 - 300    