In this step you will be shutting down one or more jobs, systems,
or both to recover the hung connector(s). If it becomes necessary
to shut down more than one job or system, consider shutting down one
job or system at a time and then check to see if that action recovered
the hung connector. If not, proceed to the next job or system shut
down.
- If a job was identified as a candidate for recovery actions, shut
down that job.
- If a system was identified as a candidate for recovery actions,
shut down that system.
- If no jobs or systems were identified as candidates for recovery
actions, shut down all jobs containing ACTIVE connectors to the structure
with hung connectors.
After the shut down is complete, display the structure by issuing
the following command:
DISPLAY XCF,STRUCTURE,STRNAME=strname
Examine the output of the command (IXC360I) and locate information
about the structure connections. (In the following example, IRLMA
on SYS1 was shut down.)
CONNECTION NAME ID VERSION SYSNAME JOBNAME ASID STATE
----------------- -- -------- -------- -------- ---- ------
IRLMGRP1$IRLA001 03 0003002F SYS1 IRLMA 001D FAILED-
PERSISTENT
IRLMGRP1$IRLB002 02 0002008C SYS2 IRLMB 0058 ACTIVE
IRLMGRP1$IRLC003 01 00010099 SYS3 IRLMC 003F FAILED-
PERSISTENT
- If the FAILING and DISCONNECTING states have been resolved as
indicated by the FAILING connector entering a FAILED-PERSISTENT or
undefined state, and the DISCONNECTING connection becoming undefined,
reinitialize the jobs that were shut down. Those jobs should restart
and reconnect to the structure successfully.
- If the FAILING and DISCONNECTING states have not been resolved:
- For the structure with the hung connectors, shut down all the
remaining ACTIVE connectors. With all the active connectors shut down,
the connections should all be in an undefined state or a FAILED-PERSISTENT
state depending on the exploiter of the structure. Issue DISPLAY
XCF,STRUCTURE,STRNAME=strname and verify that all connections
have entered a FAILED-PERSISTENT or undefined state. Once verified,
restart all jobs.
- If all the connector jobs were shut down and the connections still
have not entered a FAILED-PERSISTENT or undefined state, contact XCF
Programming Support for additional assistance.