z/OS MVS Setting Up a Sysplex
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Output messages from the IXCDELNP utility

z/OS MVS Setting Up a Sysplex
SA23-1399-00

The IXCDELNP utility issues one or more of the following messages.

Input parameter not specified or too long
No PARM keyword was coded to pass the XCF note pad name as input, or the length of the PARM that was passed in was too large. For a description of the PARM keyword, see Deletion utility for XCF note pads.
Utility input: parm
parm is the input that is specified with the PARM keyword.
Specified note pad delete option is not valid
The delete option that is specified with the PARM keyword is invalid. For a description of the PARM keyword, see Deletion utility for XCF note pads.
Processing XCF note pad notepadname
The IXCDELNP utility successfully acquired the XCF note pad name notepadname from the input PARM keyword specification. The utility will attempt to delete the indicated note pad. Subsequent messages indicate the result of this delete processing.
XCF note pad deletion successful
The target note pad was successfully deleted.
XCF note pad name improperly specified
The note pad name that is specified with the PARM keyword is invalid. For a description of the PARM keyword, see Deletion utility for XCF note pads.
Specified XCF note pad does not exist
The target note pad does not exist.
Specified XCF note pad not deleted. Note pad still in use by one or more connectors.
The target note pad was not deleted because it was still in use by one or more connectors. If necessary, you can force the deletion of a note pad that has active connectors by specifying the FORCE option on the PARM keyword. For a description of the PARM keyword, see Deletion utility for XCF note pads.
No authority to note pad resources
The requester does not have the proper SAF authorization to delete the target note pad. See Authorizing XCF note pad requests for information about defining security profiles for note pad requests.
XCF Utility can not be invoked from the Master Address Space to delete a note pad
The MASTER address space cannot invoke the IXCDELNP utility. See z/OS MVS Programming: Sysplex Services Guide for information about authorization and environmental requirements for deleting a note pad.
Unexpected error. RC: return_code RSN: reason_code See IXCNOTE macro for return code and reason code explanations.
An unexpected return and reason code was returned from the IXCNOTE service. See z/OS MVS Programming: Sysplex Services Reference for IXCNOTE return and reason codes.
No security decision could be made
No security decision was made for the requester because there is either no security product installed on the system or no proper FACILITY class resource defined. See Authorizing XCF note pad requests for defining security profiles for note pad requests.
XCF Note Pad services not available on this system
XCF Note Pad services are not available on this system. The situation will persist for the life of the IPL.
The system is not configured to support access to the note pad catalog structure or note pad structure
The system is not currently configured to support note pads. See Planning XCF Note Pad Services in a sysplex for more information about setting up the XCF Note Pad Services.
Unable to obtain the system resources needed to process the request.
The IXCDELNP utility was unable to obtain the system resources that are needed to process the request. Retry the request after allowing time for the condition to clear.
The system does not have connectivity to the coupling facility that contains the note pad catalog structure.
The system does not have connectivity to the coupling facility that contains the note pad catalog structure. Try invoking the IXCDELNP utility on a different system that does have connectivity to the note pad catalog structure, or retry the request after the system regains connectivity.
The system does not have connectivity to the coupling facility that contains the note pad structure
The system does not have connectivity to the coupling facility that contains the note pad structure. Try invoking the IXCDELNP utility on a different system that does have connectivity to the note pad structure, or retry the request after the system regains connectivity.
A structure is temporarily unavailable due to system managed processing against the note pad catalog structure or note pad structure
The note pad catalog structure or the note pad structure is temporarily unavailable due to system managed processing. Retry the request after allowing time for the condition to clear.
The note pad is quiesced. Requests to process a note pad are rejected when a note pad is quiesced.
The note pad is quiesced, and the system was unable to process the delete request for the note pad. Retry the request after allowing time for the condition to clear.
XCF component error
The delete request failed due to an XCF component error.
Specified note pad name is too long
The note pad name that is specified with the PARM keyword is invalid. For a description of the PARM keyword, see Deletion utility for XCF note pads.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014