Loss of connectivity to the coupling facility structure z/OS MVS Setting Up a Sysplex SA23-1399-00 |
|
If a structure was in duplex-mode and a loss of connectivity occurs to only one instance of the structure (due to a hardware link failure), then XES will automatically switch from duplex-mode to simplex-mode. Logger will only be notified of the mode switch change and will not be aware of any loss of connectivity to the structure. See When the coupling facility structure duplex/simplex mode changes for how Logger handles mode switches for the structure. For a simplex-mode structure, Logger detects the loss of connectivity to the single instance of the structure. Then, based on the rebuild threshold specified, if any, in the structure definition in the CFRM policy, the system that lost connectivity may initiate a rebuild for the structure. If a rebuild is initiated, the event 48 parameter list mapped by macro IXGENF has bits IXGENFLogStreamsNotAvailable, and IXGENFStrRebuildStart, on, and field IXGENFStrName contains the name of the coupling facility structure affected. System logger rejects logger service requests issued during the rebuild process. If XES cannot allocate a new structure instance in
a coupling facility that can be connected to all the affected systems,
system logger does one of the following, depending on whether the
system or systems that cannot connect to the new coupling facility
structure were using staging data sets:
|