/* Paths out. */

z/OS MVS Setting Up a Sysplex
SA23-1399-00

  • PATHOUT STRNAME(IXCAPP) CLASS(TCNEW) - defines signaling structure IXCAPP for outbound traffic. Outbound signaling paths will be established with every other system that defines IXCAPP for inbound traffic. These outbound signaling paths are assigned to transport class TCNEW. Outbound messages for group NEWAPP are sent via IXCAPP.
  • PATHOUT DEVICE(11FE) CLASS(TCNEW) - assigns outbound signaling path 11FE to class TCNEW. Outbound messages for group SYSAPP are sent on this path.
  • PATHOUT STRNAME(IXCDEF) - defines signaling structure IXCDEF for outbound use. Outbound signaling paths will be established with every other system that defines IXCDEF for inbound use. Since no transport class is explicitly specified for this structure, MVS™ assigns the outbound paths to the DEFAULT class. Outbound messages for all groups, other than SYSAPP, are sent via IXCDEF
  • PATHOUT DEVICE(101) - defines outbound signaling path 101. MVS assigns the outbound path to the DEFAULT class. Outbound messages for all groups, other than SYSAPP, are sent on this path.