System-Initiated alter processing may not start an alter for an
eligible structure when any of the following conditions exist:
- A previously initiated Alter (either system-initiated or initiated
by other means) is already in progress for the structure or has recently
completed (with alter related events still pending delivery to structure
exploiters).
- A cache structure's total in use (changed and unchanged)
percentage of directory entries exceeds 95%, but the entry/element
ratio exceeds a value of 255:1.
- A structure is already at the maximum size defined
by the CFRM policy and the entry/element ratio exceeds a value of
255:1..
- A structure is already at the maximum size defined by the CFRM
policy and the current utilization of entries and elements does not
require a ratio change (the currently allocated ratio of structure
objects is in line with the ratio of structure objects currently being
used).
- A structure is already at the maximum size defined by the CFRM
policy and the target entry/element ratio calculated by the system-initiated
alter processing is equal to the ratio requested on the last alter
or allocation request, regardless of whether or not that alter process
attained its targets.
- A list structure is already at the maximum SIZE defined by the
CFRM policy and the target entry/element ratio and the EMC storage
percentage calculated by the system-initiated alter processing is
equal to the ratio and EMC storage percentage requested on the last
alter or allocation request, regardless of whether or not that alter
process attained its targets.
- A structure's current utilization of entries and elements does
not require a ratio change (the currently allocated ratio of structure
objects is in line with the ratio of structure objects currently being
used) and there is no free space in the coupling facility into which
to expand the structure.
- A coupling facility as a whole is above 90% full and an eligible
structure within that coupling facility contains monitored objects
that are not above the structure full threshold specified by FULLTHRESHOLD,
but one or more of the monitored object types are sufficiently close
to the structure full threshold that an alter initiated to contract
the structure might push one or more of the monitored objects over
the full threshold value.
- A coupling facility as a whole is above 90% full and an eligible
structure within that coupling facility contains monitored objects
that are not above the structure full threshold specified by FULLTHRESHOLD,
but the currently allocated structure size is sufficiently small that
an alter initiated to contract the structure might push one or more
of the monitored objects over the full threshold value.
See topic Requesting structure size for more information about requesting
the size for structures. See topic CFRM parameters for administrative data utility for more