z/OS MVS Setting Up a Sysplex
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Handling concurrent system and couple data set failures

z/OS MVS Setting Up a Sysplex
SA23-1399-00

It is possible to have concurrent loss of couple data sets, systems, and other sysplex resources if a disaster, such as a power failure, occurs. Concurrent failure of one or more couple data sets and one or more systems requires a special recovery procedure. In the event that a concurrent failure occurs, XCF issues message IXC256A. If the systems identified in message IXC256A are in an unrecoverable state (such as a disabled wait state or a loss of power), those systems must be removed from the sysplex to allow couple data set recovery to proceed.

Remove each of the systems identified in message IXC256A as follows:

  1. Perform a system reset on each system identified in IXC256A.
  2. From an active system in the sysplex, issue the following command, where sysname is the name of the system identified in IXC256A.
    VARY XCF,sysname,OFFLINE
  3. From the same active system used in the preceding step, issue the following command, where sysname is the name of the sysname used in the preceding step.
    VARY XCF,sysname,OFFLINE,FORCE

Go to the previous page Go to the next page