z/OS MVS Setting Up a Sysplex
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Requirements for participating in automatic restart management

z/OS MVS Setting Up a Sysplex
SA23-1399-00

To participate in automatic restart management,
  • Your system must be running supported versions of z/OS and JES2 or JES3.
  • A system must be connected to an ARM couple data set with an active automatic restart management policy.
  • A batch job or started task must register with automatic restart management. (That is, it must issue the IXCARM macro. See z/OS MVS Programming: Sysplex Services Guide for more information on the IXCARM macro.)
    Note: A batch job or started task registered with automatic restart management can only be restarted within the same JES XCF group. (That is, JES2 MAS or JES3 complex.)
  • The XCF address space must have adequate authorization through the z/OS® Security Server (RACF®) or an equivalent security product.

    In order to perform restarts, ARM must issue operator commands from the XCF address space (XCFAS). You must be certain that the XCFAS has enough authority to issue any commands required to restart a failed element. If you are using ARM, IBM® recommends that your RACF support personnel define the XCFAS in the RACF STARTED class or the started procedures table with the trusted attribute. See z/OS Security Server RACF Security Administrator's Guide for information about using the STARTED class. See z/OS Security Server RACF System Programmer's Guide for information about using the started procedures table.

Go to the previous page Go to the next page