Specifying SMS parameters through SETSMS and SET SMS

After you have activated an SMS configuration, you can use the SET SMS or SETSMS operator commands to specify SMS parameters, as follows:
Note: Some parameters in the IGDSMSxx parmlib member are read at IPL time, but do not have any effect unless it is the first time the parameters are specified for a new configuration. As indicated in the section "Changing IGDSMSxx Parameters to Support the Coupling Facility" inz/OS DFSMSdfp Storage Administration, you must issue the SETSMS command for any changes to take effect. In particular, the values used by VSAM RLS for the following keywords are remembered from last initialization, but not overridden by the IGDSMSxx specifications at IPL time unless the SETSMS command is issued.
  • CF_TIME
  • DEADLOCK_DETECTION
  • RLS_MAXCFFEATURELEVEL
  • RLS_MAX_POOL_SIZE
  • RLSABOVETHEBARMAXPOOLSIZE
  • RLSFIXEDPOOLSIZE
  • SMF_TIME

For more information about using SETSMS and SET SMS, see z/OS MVS System Commands.