The following rules apply to the creation of IECIOSxx:
- Use columns 1 through 71 for data; columns 72 through 80 are ignored.
- Continuation is indicated by a comma followed by one or more blanks.
The next record can start in any column.
- If a verb can have multiple keywords, they can be expanded to
multiple records, however, a keyword and its value must be specified
on the same record.
- An asterisk (*) in column 1 indicates a comment record. Comment
records cannot be continued and that comments cannot appear in a parameter
record.
- Each record must start with MIH, HOTIO, TERMINAL, FICON, STORAGE,
CAPTUCB, EKM, or RECOVERY followed by one or more blanks, or must
be a valid CTRACE, MIDAW, HYPERPAV, HYPERWRITE, or
ZHPF specification in the format given as follows.
- If duplicate keywords are found, the last occurrence of the keyword
is used.
- Two different verbs cannot be specified in the same record.
- The format for each record is as follows. The following sections
describe the IECIOSxx I/O-related parameters and list-specific syntax
requirements.
MIH parameter[,parameter]. . .
MIH IOTIMING mm:ss,parameter[,parameter]. . .
HOTIO parameter[,parameter]. . .
TERMINAL parameter[,parameter]. . .
CTRACE(parmlib_member_name)
FICON parameter
STORAGE parameter
CAPTUCB parameter
MIDAW=parameter
HYPERPAV=parameter
HYPERWRITE=parameter
EKM parameter
RECOVERY parameter
ZHPF=parameter