The following rules apply to the creation of IEAAPFxx:
- Enter data only in columns 1 through 71. Do not enter data in
column 72 through 80; the system ignores these columns.
- Place only one library name and corresponding volume serial number
on a line (record).
- Duplicate data set names are valid.
- On each record, first enter the library name, then one or more
blanks, then one of the following:
- The volume serial number of the volume on which the library resides.
- ****** (six asterisks), to indicate that the library resides
on the current SYSRES volume.
- *MCAT*, to indicate that the library resides on the volume
that contains the master catalog.
- Nothing, to indicate the library is SMS-managed.
- To continue to another record, place a comma after the volume
serial number. Omit this comma on the last record.
first record: SYS1.SUPER.UTILS 614703,
second record: W12.PAYROLL.LOADLIB 705650
- On a line, data entered after the comma is treated as a comment
and ignored.
- Data records entered after the last data line are treated as comments
and ignored.
SYS1.SUPER.UTILS 614703, Super utilities
SMS.MANAGED.LOADLIB , No vol=>SMS managed
W12.PAYROLL.LOADLIB 705650, /* Payroll programs */
Xll.LOADLIB 345000 /* Last line */
This line and any following lines are ignored.
- For an SMS-managed volume, use only standard comments (delimited
by /* and */) on the last line.
SYS1.SUPER.UTILS 614703, Super utilities
SMS.MANAGED.LOADLIB1 , No vol=>SMS managed
W12.PAYROLL.LOADLIB 705650, Payroll programs
Xll.LOADLIB 345000, /* X11 programs */
SMS.MANAGED.LOADLIB2 /* Last line */