z/OS MVS Programming: Authorized Assembler Services Reference ALE-DYN
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


CTRACEWR - List form

z/OS MVS Programming: Authorized Assembler Services Reference ALE-DYN
SA23-1372-00

Syntax

The list form of the CTRACEWR macro is written as follows:

Syntax Description
   
   name name: Symbol. Begin name in column 1.
   
One or more blanks must precede CTRACEWR.
   
CTRACEWR  
   
One or more blanks must follow CTRACEWR.
   
,MF=(L,cntl) cntl: Symbol.
,MF=(L,cntl,attr) attr: 1- to 60-character input string.
,MF=(L,cntl,0D) Default: 0D
   

Parameters

The parameters are explained as follows:

,MF=(L,cntl)
,MF=(L,cntl,attr)
,MF=(L,cntl,0D)
Specifies the list form of the macro.

cntl is the name of a storage area for the parameter list.

attr is an optional 1- to 60-character input string, which can contain any value that is valid on an assembler DS pseudo-op. You can use this parameter to force boundary alignment of the parameter list. If you do not code attr, the system provides a value of 0D, which forces the parameter list to a doubleword boundary.

Go to the previous page Go to the next page