z/OS DFSMSrmm Implementation and Customization Guide
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EDG_EXIT200 installation exit routine return codes

z/OS DFSMSrmm Implementation and Customization Guide
SC23-6874-00

Table 1 shows the contents of register 15 upon return from each exit module.

If all exit modules return return code 0, DFSMSrmm processes the updated parameter list and return to scratch processing continues. When any exit module fails, either because it abends or because it returns any return code other than 0, return to scratch for the volume is skipped. When any exit module abends, return to scratch processing is disabled for the remainder of the EXPROC run.

Table 1. EDG_EXIT200 installation exit routine return codes
Return Code Description
0 Processing was successful. The parameter list might have been updated by the exit module.
16 The exit module determined that the parameter list passed to it did not conform to the correct specifications.

Go to the previous page Go to the next page