z/OS DFSMS OAM Planning, Installation, and Storage Administration Guide for Tape Libraries
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Return and reason codes for CBRXLCS PTPMC

z/OS DFSMS OAM Planning, Installation, and Storage Administration Guide for Tape Libraries
SC23-6867-00

Table 1 represents the reason codes that are associated with each of the return codes returned by the function PTPDATA.

For field LCSRCODE, the return code is placed in register 15 and in the LCSPL. For field LCSREAS, the return code is placed in register 0 and in the LCSPL.

Table 1. PTPDATA return and reason codes
Return code Error type Reason code Meaning
0 Successful 0 Successful.
4 Warning   No warnings returned by PTPDATA.
8 Invalid request 9 Required type parameter not specified.
    11 Invalid value specified for type.
    12 Required function parameter not specified.
    13 Invalid value specified for function.
    23 Required library name parameter not specified.
    27 Invalid library name specified.
    29 Invalid parameter address specified for LCSPL.
    30 LCSPL not aligned on fullword boundary.
    218 Required DATATYPE keyword not specified.
12 Failure 59 Failure accessing library record in TCDB.
    61 Device services failure.
    64 Library record not found in TCDB for requested library.
    81 Unable to obtain storage for TDI information.
    84 Abend occurred during LCS External Services processing.
    312 Function is not compatible with the library (the request cannot be performed by the library due to its current state, its configuration, or set of installed features).
    322 Command rejected by the library.
16 Environment 80 LCS External Services unable to establish ESTAE.

Go to the previous page Go to the next page