Listing Subsystem Counters for All Devices on Similar Subsystems: Example 3 z/OS DFSMS Access Method Services Commands SC23-6846-01 |
|
In this example, a Subsystem Counters report for all devices on
all like subsystems is requested.
The OUTDS DD statement allocates the output data set (DSN=OUTDATA)
on a 3390 for use by the LISTDATA command. If an output data set is
not allocated, the report is printed on the SYSPRINT data set. The
DCB parameter is required for the alternate output data set. The output
data set is cataloged in the master catalog (DISP=(,CATLG)). This
DD statement allocates two cylinders for the output data set and,
if more space is required for the report, the space is extended in
increments of one cylinder. The LISTDATA command parameters are:
|