MSGDISP—Execute form

z/OS DFSMS Macro Instructions for Data Sets
SC23-6852-02

The execute form of the MSGDISP macro is:

RDY
DCB=addr—RX-Type address or (2-12)
MF=(E,addr)
specifies that the execute form of MSGDISP and an existing parameter list is to be used.
addr—RX-Type address, (1), or (2-12)
specifies an in-storage address of the parameter list.
TXT={'msgtxt'|addr}
'msgtxt'
specifies the 1- to 6-character text. The text must be enclosed in apostrophes.
addr—RX-Type address or (2-12)
specifies an in-storage address of an area containing the six bytes of text to be displayed.