z/OS DFSMS Using Data Sets
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Data Integrity Messages

z/OS DFSMS Using Data Sets
SC23-6855-00

Although the data integrity function is designed to prevent multiple applications from opening or updating the same sequential data set concurrently, data integrity processing might miss occasional violations while in warning mode, or if the data set is excluded from protection. For example, if two applications repeatedly open and close the same data set for input or output while in warning mode, data integrity processing might miss the violation, depending on the open/close sequence. This situation is not a problem when the application is running in ENFORCE mode.

Table 1 describes the different conditions for when data integrity is disabled and also for data integrity warnings.

Table 1. Messages for data integrity processing
Mode Condition Message SMF Record Result
MODE(DISABLE) Enhanced data integrity is not active (even if no data set names are in the enhanced data integrity table).     Sequential data sets can be opened for output concurrently.
IFGPSEDI not in SYS1.PARMLIB Enhanced data integrity is not active.     Sequential data sets can be opened for output concurrently.
MODE(WARN) If the data set is being opened for input when it is already opened for output, and the data set name is not in the enhanced data integrity table, and the application does not bypass enhanced data integrity. IEC984I SMF type 14

SMF14INO flag

The data set is opened.
MODE(WARN) If the data set is being opened for output when it is already opened for output, and the data set name is not in the enhanced data integrity table, and the application does not bypass enhanced data integrity. IEC984I SMF type 15

SMF14OPO flag

The data set is opened.
MODE(WARN) If the data set is being opened for input when it is already opened for output, and the data set name is in the table or the application bypasses enhanced data integrity. IEC985I SMF type 14

SMF14EXT flag
(if in EDI table) or
SMF14EPS flag
(if bypass requested)

The data set is opened.
MODE(WARN) If the data set is being opened for output when it is already opened for output, and the data set name is in the table or application bypasses enhanced data integrity. IEC985I SMF type 15

SMF14EXT flag
(if in EDI table) or
SMF14EPS flag
(if bypass requested)

The data set is opened.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014