IRRV001I

z/OS Security Server RACF Messages and Codes
SA23-2291-00

IRRV001I
RACF command envelope ended in abend processing.

Explanation

An internal error occurred. RACF® experienced an abend while handling a prior abend. The initial abend code should be listed in message IRRV080, which was issued before this one. This message is sent to the user's TSO terminal or the operator console, depending on where the command was issued, or this message is appended to the user's RRSFLIST data set. If the data set is full, this message is transmitted to the user's TSO terminal.

System action

Processing is halted at the time of the abend.

User response

If you were performing an update type command (for example, ALTUSER), you can use the appropriate list command (for example, LISTUSER) to determine if the update occurred before the abend. If the problem persists, contact your RACF support personnel and report the abends to the IBM® support center. Be sure to indicate the abend code and reason code that were reported in the message.

Problem determination

Examine the console log and the system abend dump for more information pertaining to the abends.