z/OS Security Server RACF Messages and Codes
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


IRR65035I

z/OS Security Server RACF Messages and Codes
SA23-2291-00

IRR65035I
Database LOCKINPUT/UNLOCKINPUT parameters are not permitted while the system is in read-only mode.

Explanation

LOCKINPUT/UNLOCKINPUT attempts to update the extend bit in the ICB. However, no database updates can be made while the system is in read-only mode.

System action

Utility processing stops.

System programmer response

You can do one of the following tasks:
  • Run IRRUT400 with a parameter of LOCKINPUT/UNLOCKINPUT from another system that is not in read-only mode.
  • Issue RVARY DATASHARE to change the mode of all systems to data sharing mode and rerun the job.
  • Issue RVARY NODATASHARE to change the mode of all systems to non–data sharing mode and rerun the job.

Go to the previous page Go to the next page