ICH554I z/OS Security Server RACF Messages and Codes SA23-2291-00 |
|
ICH554I NUMBER OF RESIDENT DATA BLOCKS SPECIFIED IN ICHRDSNT FOR
DATABASE dbname IS INSUFFICIENT FOR SYSPLEX COMMUNICATION.
DEFAULT OF 50 FOR PRIMARY AND 10 FOR BACKUP WILL BE USED. ExplanationWhen installed for sysplex communication, RACF® requires a minimum of 50 resident data blocks for the primary and a minimum of 10 resident data blocks for the backup. The number of resident data blocks specified for the primary is less than 50 for the indicated database. System actionRACF allocates a default of 50 resident data blocks for the primary and 10 resident data blocks for the backup for this IPL and continues initialization. Operator responseNotify the systems programmer. System programmer responseUpdate the data set name table (ICHRDSNT) to specify at least 50 resident data blocks for the indicated database before the next IPL. Routing code2 Descriptor code4 |