Required/Optional Statement |
Required |
Statement Default |
None |
Placement in Initialization Stream |
This statement must precede the ENDJSAM statement. |
Coding Considerations |
- The maximum number of TRACK statements is 1024.
- The TRACK statement should replace the FORMAT statement after
each spool data set has been formatted. The SPART parameter specification
on the TRACK statement must match the NAME parameter on a SPART statement.
|
Security Usage |
None |
Performance Considerations |
None |
Initialization Stream Overrides |
None |
Restart or Command Modification |
Cold start, warm start, or hot start with
refresh for all parameters. When warm starting JES3, if the
STT or STTL parameter was specified on a FORMAT statement that is
being replaced by a track statement. The STT or STTL parameter must
also be specified on the TRACK statement. You can also use a warm
start to replace FORMAT statements with TRACK statements if the corresponding
spool data set is already formatted.
*MODIFY CONFIG can be used to add, remove or modify TRACK statements.
|