The contents of the registers on entry to this exit are:
- Register
- Contents
- 0
- A logon or logoff indication having the following meanings:
- 0
- indicates syntax processing for a normal logon
- 4
- indicates logon processing for a normal logon after logon parameters
have been processed
- 8
- indicates logoff processing
- 12
- indicates autologon processing
- 1
- Address of a 5-word parameter list having the following structure:
- Word 1 (+0)
- address of the remote attribute table (RAT) when R0 indicates a normal logon process
of “0”
address of a RAT entry when R0 indicates other than
a normal logon process (that is, R0 contains a value of 4, 8, or 12).
- Word 2 (+4)
- 0 during syntax processing (that is, R0=0)
- address of the line DCT after logon is complete (that is, R0≠0)
- Word 3 (+8)
- address of the ICE
- Word 4 (+12)
- address of the bind user data when R0 indicates normal logon
processing (that is, R0=0). The format of the bind user data is determined
by installation VTAM® application programs that define
the bind user data.
- Word 5 (+16)
- length of the bind user data when R0 indicates normal logon
processing (that is, R0=0).
- 2-10
- N/A
- 11
- Address of the HCT
- 12
- N/A
- 13
- Address of the line manager PCE
- 14
- Return address
- 15
- Entry address