Each connection requires 100KB of virtual storage.
SNALINK provides its own BIND parameters, so it does not assume
or require any particular LOGMODE entries.
The EAS value should be two times the number of maximum sessions
passed to the SNALINK cataloged procedure.
SRBEXIT=YES.
You might have to specify pacing values (VPACING). Consult your VTAM® network administrator for
further details.
For max_ru_size, be sure to consider
the size of the TH, RH, and RU portions. If the maximum size PIU exceeds
MAXRU, the NCP issues a negative response with sense 800A0000 (PIU
too long). The definition used in NCP and SNALINK must be such that
MAXRU is at least 29 bytes less than MAXDATA. See z/OS Communications Server: SNA Network Implementation
Guide for more information on defining the MAXDATA,
MAXBFRU, and UNITSZ operands.