DEFAULTPRTSPEC or SDEFAULTPRTSPEC statement

Use the optional DEFAULTPRTSPEC or SDEFAULTPRTSPEC object and mapping statements to define a list or range of printer LUs with a default mapping to the NULL client identifier. This LU pool is used by a printer emulator requesting a specific connection if no other printer LU group maps specifically or generically to the client. The SDEFAULTPRTSPEC statement defines shared LU names rather than private ones.

Restrictions:
  • This Telnet must have joined the XCF group to define shared objects. An active Telnet LU name server (LUNS) must exist in order for the profile to be processed and for the shared LUs to be usable.
  • A profile can have either DEFAULTPRTSPEC or SDEFAULTPRTSPEC defined, but not both.

Syntax

Read syntax diagramSkip visual syntax diagram
                               .--------------------------------------------.                      
                               V                                            |                      
>>-DEFAULTPRTSPEC--+--------+----+-prt_name-------------------------------+-+--ENDDEFAULTPRTSPEC-->
                   '- ,nnn%-'    '-prt_name1..prt_name2--+--------------+-'                        
                                                         '-..range_rule-'                          

                                .--------------------------------------------.                       
                                V                                            |                       
>--SDEFAULTPRTSPEC--+--------+----+-prt_name-------------------------------+-+--ENDSDEFAULTPRTSPEC-><
                    '- ,nnn%-'    '-prt_name1..prt_name2--+--------------+-'                         
                                                          '-..range_rule-'                           

Parameters

nnn%
Checks the capacity remaining in the group when Telnet assigns an LU from that group. A message is issued when the specified percentage is reached. After the group exceeds the specified capacity, no other message is issued. After the capacity drops below 10 percent of the total capacity check amount, another capacity warning message is issued. Leave a blank space between DEFAULTLUS or SDEFAULTLUS and the comma (,) that is part of the capacity field.
prt_name
The name of the printer LU.
prt_name1..lu_name2
A range of printer LUs.
range_rule
The wildcard method used for each character position.

Usage notes

See Rules for LU name specification for LU name and LU range specification rules.