EZD1639I
THE DEFENSIVEFILTERDIRECTORY VALUE MAY NOT BE CHANGED BY A REFRESH OPERATION - IN USE initialdirectory FAILED refreshdirectory

Explanation

The Defense Manager daemon (DMD) configuration file used for the MODIFY REFRESH command contained a different DefensiveFilterDirectory value than the DMD configuration file with which DMD was started. If DefensiveFilterDirectory was not specified in the REFRESH configuration file the default value /var/dm/filters was used. The defensive filter directory cannot be changed with a MODIFY REFRESH command. Stop DMD, then restart DMD with the new defensive filter directory.

In the message text:
initialdirectory
The name of the defensive filter directory with which DMD was started.
refreshdirectory
The name of the defensive filter directory in the REFRESH configuration file that was rejected.

System action

Processing of the configuration file stops. No changes are committed and the daemon continues using the old configuration values.

Operator response

If the DMD should use a different defensive filter directory than the one with which it was started, stop and restart DMD with the configuration file containing the new defensive filter directory name.

System programmer response

None.

User response

Not applicable.

Problem determination

None.

Source

z/OS® Communications Server TCP/IP: Defense Manager daemon

Module

Not applicable.

Routing code

10

Descriptor code

12

Automation

Not applicable.

Example

EZD1639I THE DEFENSIVEFILTERDIRECTORY VALUE MAY NOT BE CHANGED BY A REFRESH OPERATION - IN USE 
         /var/dm/filters FAILED /var/dm/filters1