z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZD1583I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD1583I
PAGENT MODIFY COMMAND UNSUCCESSFUL - application NOT CONFIGURED FOR MONITORING

Explanation

A MODIFY command was issued to the Policy Agent to start, restart, or stop an application, but the application is not configured for monitoring on the AutoMonitorApps configuration statement.

In the message text:
application
The name of the application that was specified on the MODIFY command. If the application runs one instance per stack, the corresponding TCP/IP stack name precedes the application name, separated by a forward slash (/).

System action

The MODIFY command is ignored.

Operator response

See the system programmer response.

System programmer response

If you want to monitor the application, configure the application for monitoring. See the information about configuring Policy Agent to automatically monitor applications in z/OS Communications Server: IP Configuration Guide and the AutoMonitorApps statement in z/OS Communications Server: IP Configuration Reference for.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP: Policy Agent (PAGENT)

Module

pzosinit

Routing code

10

Descriptor code

12

Automation

Not applicable.

Example

F PAGENT,MON,START,DMD

EZD1583I PAGENT MODIFY COMMAND UNSUCCESSFUL - DMD NOT CONFIGURED FOR  MONITORING

Go to the previous page Go to the next page