EZD1297I
tcp_name is unable to set EXPLICITBINDPORTRANGE in the sysplexports structure

Explanation

An attempt to set the explicit bind port range in the sysplexports coupling facility structure failed. This attempt was made during the processing of a GLOBALCONFIG statement with the EXPLICITBINDPORTRANGE parameter specified. The failure might be caused by a loss of access to the sysplexports structure, either as a result of a structure rebuild or a structure disconnect.

In the message text:
tcp_name
The name of the TCP/IP stack.

System action

TCP/IP processing continues. No explicit bind port range processing is performed on this stack.

Operator response

In the console log, check for any failure or rebuild messages referencing the sysplexports structure (the sysplexports structure name will be in the format EZBEPORTvvtt, where the vv value is the VTAM® XCF group ID specified as a VTAM start option and the tt value is the TCP XCF group ID specified in the TCP profile on the GLOBALCONFIG statement.) If a structure rebuild was in process for the sysplexports structure used by this stack, wait for the rebuild to complete and issue a VARY TCPIP,,OBEYFILE command specifying a file containing the GLOBALCONFIG EXLICITBINDPORTRANGE statement. If VTAM lost connectivity to the structure, issue the VARY NET,CFS,ACTION=CONNECT,STRNAME=structure_name command to re-establish connectivity to the structure. When connectivity is re-established, issue a VARY TCPIP,,OBEYFILE command specifying a file containing the GLOBALCONFIG EXLICITBINDPORTRANGE statement. If neither of the previous conditions are true, contact the system programmer.

System programmer response

Take a dump of TCP stack address space, the VTAM address space, and the sysplexports structure and contact the IBM® Software Support Center.

User response

Not applicable

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP

Module

EZBXFUT6

Routing code

2,8

Descriptor code

12

Example

EZD1297I TCP1 is unable to set EXPLICITBINDPORTRANGE in the sysplexports structure