Received message is a replay message

Explanation

The Internet Key Exchange (IKE) daemon detected a message that was already processed.

Additional diagnostic messages that have the same message instance number will be issued to identify the impacted Security Association (SA). The message instance number precedes the message number in the log output and is used to group related messages from the IKE daemon.

System action

The message is not processed; IKE daemon processing continues.

Operator response

Replays are not errors and can be caused by lost packets, network congestion. Usually, no action is required. If there are a large number of replays, notify the administrator of the remote security endpoint that you are receiving a large number of replays.

System programmer response

None.