z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZD0968I

z/OS Communications Server: IP Messages Volume 2 (EZB, EZD)
SC27-3655-01

EZD0968I
Unknown or incorrect address type ( address_type ) in Security Association address

Explanation

The specified address type in the SA is unsupported.

Additional diagnostic messages that have the same message instance number will be issued to identify the impacted Security Association (SA). The message instance number precedes the message number in the log output and is used to group related messages from the IKE daemon.

In the message text:
address_type
The number of the unsupported address type

System action

The SA negotiation failed; IKE daemon processing continues.

Operator response

Contact the system programmer.

System programmer response

Request that the administrator of the remote security endpoint check their policy and ensure that only supported addresses are being used.

Module

sa_addr.cpp

Procedure name

None.