Explanation

While encoding or decoding the presentation element for the SNMP version number in an SNMP request, the SNMP Query Engine was expecting the presentation element to have a version number of 0 (SNMP version-1). The SNMP request is discarded.

System action

Processing continues with the next request.

Operator response

If the error persists, tell the system programmer about the error.

System programmer response

For errors in decoding incoming SNMP requests, run traces (either the SNMP Query Engine traces or some form of LAN analyzer traces) to determine whether the encoded stream was in error or if the SNMP Query Engine was in error. If the encoded stream was in error, contact the appropriate support center for the SNMP client or agent that sent the request. If the received encoded request is correct, then the SNMP Query Engine is parsing the request incorrectly. Contact the IBM® Software Support Center. For errors encoding an SNMP response or trap PDU to be sent out, contact the IBM Software Support Center.

Module

SNMPTYPE

Procedure name

decode_SNMP_Message, encode_SNMP_Message