z/OS Communications Server: IP Messages Volume 1 (EZA)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZA2842I

z/OS Communications Server: IP Messages Volume 1 (EZA)
SC27-3654-00

System service invoked for load module transfer failed: IEBCOPY rc=rc

Explanation

While performing a load module transfer, the client invoked the IEBCOPY system utility to unload load modules into a temporary data set (for PUT or MPUT) or to reload unloaded load modules from temporary data set into the target load library (for GET or MGET). IEBCOPY failed.

rc is the decimal return code provided by IEBCOPY. IEBCOPY return codes are documented in z/OS DFSMSdfp Utilities.

System action

Load module transfer ends. No files will be transferred. The FTP client waits for the next subcommand.

Operator response

Contact the system programmer

System programmer response

Use the z/OS DFSMSdfp Utilities manual to determine the corrective action for the IEBCOPY return code.

Module

EZAFTPMD

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014