z/OS Communications Server: IP Messages Volume 1 (EZA)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZA2737W

z/OS Communications Server: IP Messages Volume 1 (EZA)
SC27-3654-00

Unable to set up conversion between parm1 and parm2. SBDATACONN ignored.

Explanation

A LOCSITE subcommand has been entered with an SBDATACONN parameter. A code set convertor was successfully opened, but FTP was unable to set up single-byte translate tables using the requested code sets. The SBDATACONN parameter is ignored.

System action

FTP continues.

Operator response

Ensure that the requested code set names are for single-byte code pages. SBDATACONN is not supported for double-byte. See the z/OS XL C/C++ Programming Guide for information on supported code set converters and valid code set names.

System programmer response

No action is needed.

Module

EZAFTPCK

Go to the previous page Go to the next page