z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ9371I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ9371I
isc_timer_reset(): error_text

Explanation

The named server failed to get the time of day while resetting the resolver timer to an inactive state. The time returned might not be accurate.

error_text describes the error.

System action

The named server continues.

Operator response

Use the z/OS® UNIX date command to ensure that the CPUs date is correct. See the z/OS UNIX System Services Command Reference for more information about the date command.

System programmer response

None.

Module

RESOLVER

Procedure name

fctx_stoptimer

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014