z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ9362I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ9362I
could not set master file style

Explanation

The named server failed to convert the resource data set or question section because of a problem with the master file style. The data being processed might be too long or there might be insufficient buffer space to convert the data from column format.

System action

The named server continues.

Operator response

Ensure that the master file data being processed is correct. If you are unable to resolve this problem, then contact the system programmer.

System programmer response

Re-create this problem with a SYSTCPIP component trace active specifying the TC, UDP and IOCTL options and set the debug level on the named log files to 99. Obtain the following documentation and contact the IBM® software support center:
  • The named server configuration file
  • The SYSLOG DAEMON logging file
  • All configured named logs
  • The component trace requested

Module

MASTERDU

Procedure name

dns_master_dumptostream

Go to the previous page Go to the next page