EZZ9245I
isc_app_reload() kill: description

Explanation

The named server failed to reload because a thread could not be ended.

description describes the error.

System action

System action

A Language Environment® CEE dump was taken and the named server ends.

Operator response

Contact the system programmer.

System programmer response

Re-create this problem with a SYSTCPIP component trace active specifying the TC, UDP and IOCTL options and set the debug level on the named server configuration file to 99. Dump the named server address space. See the z/OS Communications Server: IP Diagnosis Guide for instructions on dumping an address space. Obtain the following documentation and contact the IBM® software support center:
  • The named server configuration file.
  • The SYSLOG DAEMON logging file.
  • All configured named logs.
  • The component trace requested. See the z/OS Communications Server: IP Diagnosis Guide for instructions on setting and producing a component trace.
  • The dump of the named address space taken when the problem was re-created.

Module

APP

Procedure name

isc_app_reload