EZZ8158I jobname ipversion OSPF
could not establish adjacency on interface interface1 -
attempting to establish adjacency on interface interface2 ExplanationThis message was issued because OMPROUTE could not establish an adjacency with a neighbor on the interface specified by the interface1 value. The neighbor is identified in message EZZ8157I. OMPROUTE found a redundant parallel interface (interface2) that can reach the same neighbor on the LAN and OMPROUTE is attempting to establish an adjacency with the neighbor. OMPROUTE will change interface1 to SUSPEND state and interface1 will remain in that state until the interface is recycled or is dynamically activated to allow an adjacency to be established. In the message text:
System actionOMPROUTE continues and will attempt to establish an adjacency with the neighbor over the redundant parallel interface. Operator responseContact the system programmer. System programmer responseIf connectivity problems persist, investigate the reason that the adjacency could not be established. Inspect the remote networking hardware components, such as routers, switches, or cabling, that might contribute to the problem. User responseNot applicable. Problem determinationSee the system programmer response. Sourcez/OS® Communications Server TCP/IP: OMPROUTE ModuleSPFNBR, EZA6RSPB Routing code10 Descriptor code12 AutomationThis message goes to the console or syslog. Example
|