EZZ7897I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ7897I
User is not RACF authorized to start jobname

Explanation

The user that attempted to start the OMPROUTE application is not RACF® authorized to start it. The user must have RACF authority to the entity MVS™.ROUTEMGR.OMPROUTE.

In the message text:
jobname
The job name of the OMPROUTE application.

System action

OMPROUTE ends.

Operator response

None.

System programmer response

Provide RACF authority to the user as described in the z/OS Communications Server: IP Configuration Guide.

Module

EZAORINI