Explanation
The application is exiting abnormally with the
specified return code.
In the message text:
- jobname
- The job name of the OMPROUTE application.
- returncode
- Possible values for returncode are:
- 1
- Exited due to unrecoverable error.
- 3
- Exited due to receipt of terminating signal.
- 4
- Exited due to invalid startup parameter passed to OMPROUTE.
- 5
- Exited due to failure to add route to TCP/IP stack's route table.
- 6
- Exited due to failure to obtain storage using malloc.
- 7
- Exited due to the TCP/IP stack going down, or the TCP/IP stack
is storage constrained, or the TCP/IP stack is otherwise unavailable.
- 8
- Exited while initializing the PSA environment.
- 9
- Exited while initializing the log/trace facility.
- 10
- Exited due to OMPROUTE not being APF authorized.
- 11
- Exited while initializing the IPv4 OSPF and INFORMATIONAL sockets.
- 12
- Exited while configuring the OMPROUTE application.
- 13
- Exited while obtaining the TCP/IP stack's IPv4 route table.
- 14
- Exited while initializing the IPv4 RIP protocol.
- 15
- Exited while initializing the IPv4 OSPF protocol.
- 16
- Exited while dynamically adding an IPv4 OSPF interface.
- 17
- Exited due to failure to delete route from TCP/IP stack's route
table.
- 18
- Exited due to failure to change route in TCP/IP stack's route
table.
- 19
- Exited while initializing the IPv4 RIP socket.
- 20
- Exited due to failure to update TCP/IP stack's BSD Routing Parameters.
- 21
- Exited due to error establishing thread attributes.
- 22
- Exited while attempting to start subagent thread.
- 23
- Exited because of inability to originate an IPv4 router LSA.
For more information about this condition, see the information about
dynamic VIPAs and routing protocols in z/OS Communications Server: IP Configuration
Guide.
- 24
- Exited due to unrecoverable error in control block reuse code.
- 25
- Exited while initializing the IPv6 RIP socket.
- 26
- Exited while obtaining the TCP/IP stack's IPv6 route table.
- 27
- Exited while initializing the IPv6 RIP protocol.
- 28
- Exited while attempting to start IPv6 thread.
- 29
- Exited while attempting to start Informational Socket thread.
- 30
- Exited while initializing socket for IOCTL calls.
- 31
- Exited while initializing the OMPROUTE heartbeat.
- 32
- Exited while initializing the IPv6 OSPF protocol.
- 33
- Exited while dynamically adding an IPv6 OSPF interface.
- 34
- Exited while initializing the IPv6 OSPF sockets.
- 35
- Exited because of inability to originate an IPv6 OSPF LSA.
- 36
- Exited because of inability to translate MVS™ system symbols in the configuration file.
- 37
- Exited because a duplicate ROUTERID is detected.
System action
Operator response
System programmer response
Take necessary corrective action
based upon specified return code and any preceding messages indicating
the cause of the abnormal exit. Restart OMPROUTE if required.
Module