z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ3252I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ3252I
ERROR returncode IN ALLOCATING STORAGE FOR CONTROL BLOCK cbname

Explanation

An error occurred while attempting to allocate storage for the control block specified. The return code from the STORAGE OBTAIN is provided.

returncode is the return code from the storage allocation routine. See the z/OS MVS Programming: Assembler Services Reference IAR-XCT for a description of the STORAGE OBTAIN return codes.

cbname is the name of the control block for which the storage could not be obtained. The possible names are:
  • SATQ - SNMP Subagent TrapQ block
  • CDMQ - VARY/DISPLAY Command Request block
  • SATQHEAD - SNMP Subagent TrapQ Header block
  • SANQHEAD - SNMP Subagent NetmQ Header block

System action

If the storage was for a CDMQ control block, TCPIP or Telnet continues but the command process ends. If the storage was for a TRAPQ control block, the trap will not be generated.

Operator response

Notify the system programmer of the problem.

System programmer response

The storage allocation attempt was for storage in common. Expanding the CSA might alleviate the problem. See the z/OS MVS Initialization and Tuning Guide for allocating more CSA.

Go to the previous page Go to the next page