z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ3223I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ3223I
SNMP Subagent: Netman request failed for linkname rc netman_rc (seqnum)

Explanation

When an SNMP command is issued for an object from one of the ibm3172 MIB tables, and this table's cachetime expired, the subagent attempts to retrieve the information for a 3172 device or link from the 3172 ICP. If the return code from the 3172 ICP is not zero, the subagent writes this message to the syslog daemon indicating the linkname, the netman_rc, and the sequence number, seqnum, of the failing request.

System action

The subagent fails the request for the object from the ibm3172 MIB table and waits for the next request.

Operator response

If possible, re-create the problem with subagent trace level 3 and TCP/IP CTRACE active for options LCS, VTAM® and VTAMDATA. Contact the TCPIP administrator.

System programmer response

Verify that the 3172 indicated by linkname is active. The subagent trace will be written to the Syslog Daemon (syslogd) output file. See the z/OS Communications Server: IP Diagnosis Guide for information about obtaining the output of the CTRACE. Contact your IBM® support center with the syslogd and CTRACE output.

Module

EZASAIOC.C

Procedure name

sd_get_ibm3172_tbls

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014