Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
EZZ3215I z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM) SC27-3657-01 |
|
EZZ3215I SNMP SUBAGENT: COULD NOT ESTABLISH AFFINITY WITH tcpip_name (error_code/reason) ExplanationThe SNMP subagent attempted to use the z/OS® UNIX socket call, setibmopt(), to associate itself with the TCP/IP instance tcpip_name. This TCP/IP name should be the started procedure name (or identifier if the 'S member.identifer' format of the MVS™ Start command was used) of the TCP/IP instance under which the SNMP subagent is initializing. The setibmopt call failed with the displayed error_code and reason. System actionThe SNMP subagent ends. Operator responseMost likely, the TCP/IP instance's name was not defined correctly to OMVS. Check the SUBFILESYSTYPE NAME for the corresponding TCP/IP instance in the BPXPRMxx member that was used to configure OMVS. Ensure that the TCP/IP started procedure name (or identifier if the 'S member.identifier' format of the MVS Start command was used) matches the SUBFILESYSTYPE NAME. Recycle OMVS or TCP/IP if a change is necessary. The DISPLAY TCPIP operator command can be used to display all started TCP/IP instances and their names. If none of the above error conditions exist contact the system programmer. System programmer responseCorrect the error indicated by error_code and reason. ModuleEZASADPI.C Procedure namemain |
Copyright IBM Corporation 1990, 2014
|