EZZ0837I MORE THAN maxnum PFIDS SPECIFIED ON GLOBALCONFIG
STATEMENT ON LINE linenum ExplanationMore Peripheral Component Interconnect Express (PCIe) function ID values were specified on the SMCR PFID parameter on the GLOBALCONFIG statement than are currently supported. In
the message text:
System actionTCP/IP profile processing continues but the GLOBALCONFIG statement is ignored. Operator responseContact the system programmer. System programmer responseRemove the extra PFID values from the SMCR PFID parameter on linenum, then instruct the operator to issue a VARY TCPIP,,OBEYFILE command to activate the corrected profile. See GLOBALCONFIG profile statement in z/OS Communications Server: IP Configuration Reference for more information. User responseNone. Problem determinationNot applicable. Sourcez/OS® Communications Server TCP/IP: Configuration and Initialization Moduleezacfpar.c Routing codeNot applicable. Descriptor codeNot applicable. AutomationThis message is not a candidate for automation. Example
|