z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ0828I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ0828I
VIPADISTRIBUTE parm ON LINE linenum IS IGNORED WHEN DISTMETHOD IS HOTSTANDBY

Explanation

The specified parameter cannot be used on a VIPADISTRIBUTE DEFINE statement when the HOTSTANDBY distribution method is specified. The parameter is ignored.

In the message text:

parm
The parameter on the VIPADISTRIBUTE DEFINE statement
linenum
The line number in the configuration file on which the parameter is specified

System action

If processing an initial profile or VARY TCPIP,,OBEYFILE command, TCP/IP continues. The VIPADISTRIBUTE DEFINE statement is accepted, but the parameter is ignored.

This message is also displayed as part of VARY TCPIP,,SYNTAXCHECK processing when the VARY TCPIP,,SYNTAXCHECK command detects this error in a profile data set. No changes are applied to the active configuration by VARY TCPIP,,SYNTAXCHECK processing.

Operator response

Contact the system programmer.

System programmer response

Take the following steps to correct the problem:
  1. Remove the specified parameter from the VIPADISTRIBUTE DEFINE statement.
  2. If this message was displayed as a result of a VARY TCPIP,,SYNTAXCHECK command, issue the command again to verify that you have removed all syntax errors from the profile. Otherwise, issue a VARY TCPIP,,OBEYFILE command using this profile.

User response

Not applicable.

Problem determination

Not applicable.

Source

z/OS® Communications Server TCP/IP: Configuration & Initialization

Module

EZACFPVA

Routing code

10

Descriptor code

12

Automation

This message is directed to the console. You can use automation to detect and respond to TCP/IP profile errors reported during initial profile and VARY TCPIP,,OBEYFILE processing.

This message can also be displayed during VARY TCPIP,,SYNTAXCHECK processing. Because the VARY TCPIP,,SYNTAXCHECK command does not affect the active configuration, you might want to adjust your automation to ignore the configuration messages that are displayed after EZZ0061I and before EZZ0065I.

Example

EZZ0828I VIPADISTRIBUTE TIMEDAFFINITY ON LINE 5 IS IGNORED WHEN DISTMETHOD IS  HOTSTANDBY                           

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014