EZZ0611I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ0611I
type1 val1 on line lineno HAS BEEN USED PREVIOUSLY FOR type2 val2

Explanation

The value used on the specified line cannot be used again for the specified type. For example, two LINKs on an ATM DEVICE cannot use the same LIS.

System action

Profile processing continues. However, the statement is not defined properly and will be ignored.

Operator response

Correct the statement and rerun the profile. For more information about the statement, see the z/OS Communications Server: IP Configuration Reference.

System programmer response

None.

Module

EZACFMS1

Procedure name

parseFile