z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ0307I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ0307I
CONFIGURATION: An internal error occurred, the reason code is reason_code

Explanation

An error occurred in the configuration component.

reason_code is one of the following:
-1
Selectex call failed for the Autolog task. The Autolog task will be shut down.
-4
Internal error occurred. This will be one of the following:
  • The call to get the telnet socket/port failed.
  • Telnet error when trying to retrieve the stack jobname from TSEB (no TSEB found.)
-5
Should not occur - internal Telnet error.
-15
Storage obtain failed.
-17
Header contained invalid data. This might be a verson or request type that is not valid.
-18
Header length invalid.
-20
Bad contact type in header. The contact value must be either INIT_CONTACT, RECONTACT, or RESYNC. The connection is closed.
-22
Buffer too small to receive data. Input buffer is not large enough to be a protocol header.
-23
Buffer too small to be valid. Output buffer is not large enough for a response header.
-24
Bad subtype in buffer. Subtype in response does not match subtype in request.
-25
Address less than or equal to zero or Telnet client state not valid to send QUIESCE.
-26
Data in response is invalid. Telnet error in QUIESCE response.
-27
Socket descriptor too large.
-28
Socket descriptor too large.
-50
User tokens were not equal on a RESYNC request.
-52
Maximum number of retries reached for profile processing on RECONTACT.
-60
Cannot fine TSEB in main entry point for configuration subtask. Configuration task will be shut down.
-61
Cannot fine TSDB in main entry point for configuration subtask. Configuration task will be shut down.
-62
Cannot fine TSDX in main entry point for configuration subtask. Configuration task will be shut down.
-63
Socket call failed. Error trying to open the socket to the stack when processing a start or stop device.
-64
Storage obtain failed. Error when attempting to get a buffer for ioctl when processing a start or stop device.
-65
Storage obtain failed. Error when attempting to get a buffer for ioctl when processing initial device.
-66
Storage obtain failed. Error when attempting to get a buffer for ioctl when processing the VARY TCPIP,,OBEYFILE command.
-67
Setibmopt failed while processing a start or stop device. In order to have more than one TCP/IP stack connected to z/OS® UNIX, the z/OS UNIX must be configured for Common INET (CINET.) Processing is terminated
-68
Autolog initialization failed.
-69
Cannot find TSEB in main entry point for Autolog subtask. Autolog task will be shut down.
-70
Cannot find TSDB in main entry point for Autolog subtask. Autolog task will be shut down.
-71
Cannot find TSDX in main entry point for Autolog subtask. Autolog task will be shut down.
-72
Autolog error recovery failed.

System action

TCP/IP continues.

Operator response

Contact the system programmer.

System programmer response

Correct the error described by error_code. Report Internal errors to the IBM® software support center.

Module

EZACFMMN, EZACFPAR

Procedure name

main, handleInitialProfile, processObeyFile

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014