Explanation
An error occurred in the configuration component.
reason_code is
one of the following:
- -1
- Selectex call failed for the Autolog task. The Autolog task will
be shut down.
- -4
- Internal error occurred. This will be one of the following:
- The call to get the telnet socket/port failed.
- Telnet error when trying to retrieve the stack jobname from TSEB
(no TSEB found.)
- -5
- Should not occur - internal Telnet error.
- -15
- Storage obtain failed.
- -17
- Header contained invalid data. This might be a verson or request
type that is not valid.
- -18
- Header length invalid.
- -20
- Bad contact type in header. The contact value must be either INIT_CONTACT,
RECONTACT, or RESYNC. The connection is closed.
- -22
- Buffer too small to receive data. Input buffer is not large enough
to be a protocol header.
- -23
- Buffer too small to be valid. Output buffer is not large enough
for a response header.
- -24
- Bad subtype in buffer. Subtype in response does not match subtype
in request.
- -25
- Address less than or equal to zero or Telnet client state not
valid to send QUIESCE.
- -26
- Data in response is invalid. Telnet error in QUIESCE response.
- -27
- Socket descriptor too large.
- -28
- Socket descriptor too large.
- -50
- User tokens were not equal on a RESYNC request.
- -52
- Maximum number of retries reached for profile processing on RECONTACT.
- -60
- Cannot fine TSEB in main entry point for configuration subtask.
Configuration task will be shut down.
- -61
- Cannot fine TSDB in main entry point for configuration subtask.
Configuration task will be shut down.
- -62
- Cannot fine TSDX in main entry point for configuration subtask.
Configuration task will be shut down.
- -63
- Socket call failed. Error trying to open the socket to the stack
when processing a start or stop device.
- -64
- Storage obtain failed. Error when attempting to get a buffer for
ioctl when processing a start or stop device.
- -65
- Storage obtain failed. Error when attempting to get a buffer for
ioctl when processing initial device.
- -66
- Storage obtain failed. Error when attempting to get a buffer for
ioctl when processing the VARY TCPIP,,OBEYFILE command.
- -67
- Setibmopt failed while processing a start or stop device. In order
to have more than one TCP/IP stack connected to z/OS® UNIX,
the z/OS UNIX must be configured for Common INET (CINET.)
Processing is terminated
- -68
- Autolog initialization failed.
- -69
- Cannot find TSEB in main entry point for Autolog subtask. Autolog
task will be shut down.
- -70
- Cannot find TSDB in main entry point for Autolog subtask. Autolog
task will be shut down.
- -71
- Cannot find TSDX in main entry point for Autolog subtask. Autolog
task will be shut down.
- -72
- Autolog error recovery failed.
System action
Operator response
Contact the system programmer.
System programmer response
Correct the error described by error_code.
Report Internal errors to the IBM® software
support center.
Module
Procedure name
main,
handleInitialProfile, processObeyFile