z/OS Communications Server: IP Messages Volume 3 (EZY)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZY2659E

z/OS Communications Server: IP Messages Volume 3 (EZY)
SC27-3656-00

RECFM value must be one of: F, FA, FB, FBA, FBM, FBS, FBSA, FBSM, FM, FS, FSA, FSM, V, VA, VB, VBA, VBM, VBS, VBSA, VBSM, VM, VS, VSA, VSM, U, UA, or UM.

Explanation

While processing the FTP.DATA file, the FTP server encountered the RECFM parameter, but the value specified for the parameter was not a valid value. The value must be one of the values listed in the message.

System action

The line containing the RECFM parameter is ignored. Processing continues with the next line in the file.

Operator response

Contact the system programmer with the error message.

System programmer response

Correct the value of the RECFM parameter in the FTP.DATA file to be a valid record format. See the z/OS Communications Server: IP Configuration Reference for information on the parameters of the FTP.DATA file.

Module

EZAFTPEP

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014