Explanation

Success

User response

None.

Project manager response

None.

4

Explanation

A WARNING message was produced.

User response

Look at the message. Fix the problem if necessary.

Project manager response

None.

01300

Explanation

The FUNCTN parameter is not specified correctly in the input options defined for the translator. This parameter is one of the OPTIONS parameters for this translator. This parameter is passed to the translator by way of the OPTIONS= parameter for calls to the FLMCSPDB translator. This parameter is not to be confused with the FUNCTN= parameter passed to SCLM using the FLMTRNSL macro; rather, it is a secondary parameter value for the OPTIONS= parameter that is passed to the translator using the FLMTRNSL macro.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "OPTIONS=(FUNCTN=BUILD...)" or "OPTIONS=(FUNCTN=PROMOTE...)" is specified for the FLMTRNSL macro invoking the FLMCSPDB translator.

01310

Explanation

The OPTION parameter is not specified correctly in the input options defined for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "OPTION=BIND" or "OPTION=FREE" is specified as an option for the translator in the language definition.

01320

Explanation

The GROUP parameter is not specified in the input options defined for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "GROUP=@@FLMGRP" is specified as an option for the translator in the language definition.

01330

Explanation

The TOGROUP parameter is not specified in the input options defined for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "TOGROUP=@@FLMTOG" is specified as an option for the translator in the language definition.

01340

Explanation

The MEMBER parameter is not specified as a PARM input for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "MEMBER=@@FLMMBR" is specified as an option for the translator in the language definition.

Verify that OPTOVER=Y on the FLMCNTRL macro in the project definition.

01350

Explanation

The SCLMINFO parameter is not specified in the input options defined for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "SCLMINFO=@@FLMINF" is specified as an option for the translator in the language definition.

01360

Explanation

The DBRMTYPE parameter is not specified in the input options defined for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "DBRMTYPE=dbrmtype" is specified as an option for the translator in the language definition. Where dbrmtype has been defined as a valid type in the project definition.

01370

Explanation

An error occurred while executing the DB2 CLIST member.

Module

FLMCSPDB

User response

Verify that DB2® is installed and that you have invoked it correctly from the DB2 CLIST. Trace the execution of your CLIST to verify the return code.

Project manager response

None.

01380

Explanation

The DB2 CLIST member does not contain DSN commands for the group being processed.

Module

FLMCSPDB

User response

Verify that the DB2 CLIST member has code specifying the DSN commands required for the group being processed.

Project manager response

None.

01390

Explanation

The PROJECT parameter is not specified in the input options defined for the translator.

Module

FLMCSPDB

User response

None.

Project manager response

Verify that "PROJECT=@@FLMPRJ" is specified as an option for the translator in the language definition.

01420

Explanation

The data set allocation (DSALLOC) service failed.

Module

FLMCSPDB

User response

Contact the project manager.

Project manager response

Verify that SCLM skeleton FLMLIBS has all necessary allocations for the CSP/AD and/or DB2 products.

21310

Explanation

SCLM received an error initializing the DB2 CLIST.

User response

None.

Project manager response

Verify that the DB2 CLIST exists.

21320

Explanation

SCLM received an error initializing the DB2 OUT data set.

User response

None.

Project manager response

Verify that the DB2 OUT data set exists.

21330

Explanation

SCLM received an error when it attempted to copy the DB2 CLIST to the DB2 OUT data set.

User response

None.

Project manager response

Verify that the DB2 OUT data set attributes are complementary with the DB2 CLIST data set.

21340

Explanation

SCLM could not find the FLMPROXY ddname.

User response

None.

Project manager response

Verify that the FLMPROXY ddname was passed to the translator.

21370

Explanation

Non-key groups are not supported.

User response

None.

Project manager response

Delete non-key groups or re-specify non-key groups as key groups in the project definition. See return code 30108 for more detail.