ACCTINFO |
Y |
|
|
READ access allows the user to display the account
information. Issue the A line command in Library Utility (option 3.1)
or UOW (option 3.11) and retrieve account information using the ACCTINFO
service. |
AUTHCODE |
Y |
Y |
|
READ access allows the user to retrieve authcode
information using the AUTHCODE service. UPDATE access allows the authcode
to be modified using the U line command in Library Utility (option
3.1) or UOW (option 3.11) and using the AUTHCODE service. |
BUILD |
Y |
Y |
Y |
Building using build (option 4), C line command
in Library Utility (option 3.1) and UOW (option 3.11), or the BUILD
service validates the access prior to each translator step:
- READ access allows input members to be used to generate outputs.
- Where the output member does not exist, the subproject is copied
from the initial input member.
- Where the output member does exist and the subproject is not changing,
the user must have UPDATE access to the output member.
- Where the output member already exists and the subproject is to
change, the user must have ALTER access to the output member.
|
CCEXITS |
|
|
|
The CCEXITS service access will be the same
as for Edit. |
DBACCT |
Y |
|
|
READ access for the DBACCT service allows SCLM
to return the accounting information. |
DBUTIL |
|
|
|
No access validation is performed. |
DELETE |
|
Y |
|
Update access allows the D line command in Library
Utility (option 3.1) or UOW (option 3.11) and the DELETE service to
delete the member. |
DELGROUP |
|
Y |
|
UPDATE access allows the Delete from group (option
3.9) and the DELGROUP service to delete the members with subproject
with UPDATE access. |
DSALLOC |
|
|
|
No access validation is performed. |
EDIT |
Y |
Y |
Y |
Editing using edit (option 2), E line command
in Library Utility (option 3.1) and UOW (option 3.11) or the EDIT
service validates the access in this way:
- When entering EDIT:
- No access is required if a new member or an existing member with
no subproject is to be edited. UPDATE access to the subproject is
required if the member exists with a subproject.
- When saving the member:
- If saving the member with the same subproject or if the member
did not have a subproject, then UPDATE access for the subproject is
required. If saving the member with a different subproject, then ALTER
access for the existing subproject and UPDATE access for the new subproject
is required.
|
END |
|
|
|
No access validation is performed. |
EXPORT |
Y |
|
|
READ access for each of the members allows them
to be exported by means of Export (option 3.6) or the EXPORT service. |
FREE |
|
|
|
No access validation is performed. |
GETBLDMP |
Y |
|
|
READ authority allows the M line command in
Library Utility (option 3.1) and UOW (option 3.11) or the GETBLMP
service to display or retrieve the build map information. |
IMPORT |
Y |
Y |
Y |
Importing using Import (option 3.7) or the IMPORT
service validates the access depending on the status of the member:
- If the member is new, then only READ access to the subproject
is required.
- If the member exists with the same subproject, then only UPDATE
access to the subproject is required.
- If the member exists with a different subproject, then only ALTER
access for the existing member's subproject and UPDATE authority to
the incoming member's subproject is required.
|
INIT |
|
|
|
No access validation is performed. |
LOCK |
|
Y |
|
UPDATE access allows the LOCK service to lock
the member. |
MIGRATE |
|
Y |
Y |
Migrating using Migrate (option 3.3) or the
MIGRATE service validates the access depending on the status of the
part: - If the part is new or does not have a subproject, READ access
to the new subproject allows the member to be migrated.
- If the part is already defined to SCLM and subproject passed to
migrate does not match the existing subproject, then UPDATE access
is required to the existing subproject and ALTER to the new subproject.
- If the part is already defined to SCLM and subproject passed to
migrate matches the existing subproject, UPDATE access is required
to the existing subproject.
|
NEXTGRP |
|
|
|
No access validation is performed. |
PARSE |
|
|
|
No access validation is performed. |
PROMOTE |
|
Y |
|
Promoting using Promote (option 5), P line command
in Library Utility (option 3.1) and UOW (option 3.11) or the PROMOTE
service validates the access in this way: UPDATE access to each
member's subprojects is required for the promote to complete successfully.
|
RPTARCH |
|
|
|
No access validation is performed. |
SAVE |
|
Y |
|
The SAVE service validates access depending
on the status of the part: - If the part is new or does not have a subproject, READ access
to the new subproject allows the member to be saved.
- If the part is already defined to SCLM and subproject passed to
save does not match the existing subproject, then UPDATE access is
required to the existing subproject and ALTER to the new subproject.
- If the part is already defined to SCLM and subproject passed to
save matches the existing subproject, UPDATE access is required to
the existing subproject.
|
SCLMINFO |
|
|
|
No access validation is performed. |
START |
|
|
|
No access validation is performed. |
STORE |
|
Y |
|
The STORE service validates access depending
on the status of the part: - If the part is new or does not have a subproject, READ access
to the new subproject allows the member to be saved.
- If the part is already defined to SCLM and subproject passed to
save does not match the existing subproject, then UPDATE access is
required to the existing subproject and ALTER to the new subproject.
- If the part is already defined to SCLM and subproject passed to
save matches the existing subproject, UPDATE access is required to
the existing subproject.
|
TRANSFER |
|
Y |
|
UPDATE access allows transferring of ownership
using the T line command in Library Utility (option 3.1) and UOW (option
3.11) for members with a subproject. |
UNLOCK |
|
Y |
|
UPDATE access allows the UNLOCK service to unlock
the member. |
VERDEL |
|
Y |
|
UPDATE access allows the D line command in the
Audit and Version Utility (option 3.8) and the VERDEL service to delete
the version/audit record. |
VERHIST |
Y |
|
|
READ access allows the H line command in the
Audit and Version Utility (option 3.8) and the VERHIST service to
produce the version history report. |
VERINFO |
Y |
|
|
READ access allows the A and V line commands
in the Audit and Version Utility (option 3.8) and the VERINFO service
to read the version information or view the version member. |
VERRECOV |
|
Y |
|
READ access allows the C, X, and R line commands
in the Audit and Version Utility (option 3.8) and the VERRECOV service
to restore the version member. |